DELL Force10 switch and NIC Teaming

NIC teaming is a feature that allows multiple network interface cards in a server to be represented by one MAC address and one IP address in order to provide transparent redundancy, balancing, and to fully utilize network adapter resources. If the primary NIC fails, traffic switches to the secondary NIC because they are represented by the same set of addresses.

Let's assume we have the host with two NICs where primary NIC is connected to Force10 switch port 0/1 and secondary NIC to switch port 0/5. When you use NIC teaming, consider that the server MAC address is originally learned on Port 0/1 of the switch and Port 0/5 is the failover port. When the NIC fails, the system automatically sends an ARP request for the gateway or host NIC to resolve the ARP and refresh the egress interface. When the ARP is resolved, the same MAC address is learned on the same port where the ARP is resolved (in the previous example, this location is Port 0/5 of the switch). To ensure that the MAC address is disassociated with one port and re-associated with another port in the ARP table, configure the
mac-address-table station-move refresh-arp 
command on the Dell Networking switch at the time that NIC teaming is being configured on the server.

! NOTE: If you do not configure the mac-address-table station-move refresh-arp command, traffic continues to be forwarded to the failed NIC until the ARP entry on the switch times out.

UPDATE 2015-03-16:
I have just discovered another FTOS command ...
arp learn-enable
   Enable ARP learning using gratuitous ARP.

NIC Teaming solutions can leverage gratuitous ARP so it is worth to enable it in my opinion.

This command should be very beneficial on VMware environments where VMware vSwitch sends gratuitous ARP after VM is vMotioned from one ESXi host to another.
ESXi host doesn't use gratuitous arp but reverse arp (aka RARP). Anyway these two commands are beneficial for VMware vMotion.



Sunday, May 18, 2014

How to convert thick zeroed virtual disk to thin and save storage space

Last week I've been notified by my colleague about long term VMware vSphere issue described in VMware KB 2048016. The issue is that vSphere Data Protection restores a thin-provisioned disk as a thick-provisioned disk. This sounds like relatively big operational impact. However after reading VMware KB I've explained to my colleague that this is not typical issue or bug but it is rather expected behavior of VMware's CBT (change block tracking) technology and VADP (VMware API for data protection) framework. It's important to mention that it should behave like that only when you do initial full backup of thin provisioned VM which has never been powered on. In other words, if VM was ever powered on before initial backup procedure you shouldn't experience this issue.

After above explanation another logical question appeared.  
"How you can convert thick zeroed virtual disk to thin" ... when you experience weird behavior explained above and you restore your originally thin provisioned VM as thick VM. The obvious objection is to save storage space again leveraging VM thin provisioning.
My answer was to use "storage vMotion" which allows change ot vDisk type during migration. But just after my quick answer I realized there can be another potential issue with storage vMotion. If you use VAAI capable storage then storage vMotion is offloaded to the storage and it may not reclaim even zeroed vDisk space. This behavior and resolution is describe in VMware KB 2004155 named as "Storage vMotion to thin disk does not reclaim null blocks". The workaround mentioned in KB is to use offline method leveraging vmkfstools. If you want live storage migration (conversion) without downtime you would need another datastore with different block size. You can do it with legacy VMFS3 filesystem.

I decided to do a test to prove real storage vMotion behavior and know the truth. Everything else would be just speculations. Therefore I’ve test storage vMotion behavior of thick to thin migration and space reclamation in my lab where I have vSphere/ESX 5.5 and EqualLogic storage with VAAI support. To be honest the result surprised me in positive way. It seems that svMotion can save the space even I do svMotion between datastore with the same block and there is VAAI enabled.

You can see thick eager zeroed 40GB disk in screenshot below ...
Provisioned size is 44GB because VM has 4 GB RAM and therefore 4 GB swap file on VMFS.
Used storage is 40GB.

After live storage vMotion with conversion to Thin it saved the space. 
Used storage is just 22 GB.  You can see result at screenshot below ...

So I have just verified that svMotion can do what you need without downtime. And I don’t even need to migrated between datastores with different block size.

It was tested on ESX 5.5, EqualLogic firmware 6.x., and VMFS5 datastores created on thin provisioned LUNs by EqualLogic.  Storage thin provisioning is absolutely transparent to vSphere so this should not have impact on vSphere thin provisioning.


I know that this is just a workaround to the problem of VADP restore of never powered on VMDK but it works.  It converts thick to thin and is able to reclaim unused (zeroed) space insight virtual disks.

Conclusion:
vSphere 5.5 storage vMotion can convert thick VM to thin even between datastores having same block size. At least in tested configuration. Good to know. If someone else can do the test in your environment just leave the comment. It can be beneficial for others.

Tuesday, April 15, 2014

Long network lost during vMotion

We have observed strange behavior of vMotion during vSphere Design Verification tests after successful vSphere Implementation. By the way that's the reason why Design Verification tests are very important before putting infrastructure into production.But back to the problem. When VM was migrated between ESXi hosts leveraging VMware vMotion we have seen long network lost of VM networking somewhere between 5 and 20 seconds. That's really strange because usually you didn't observe any network lost or maximally lost of single ping from VM perspective.

My first question to implementation team was if  virtual switch option "Notify Switch" is enabled as is documented in vSphere design. The importance of this option is relatively deeply explained for example here and here. The answer from implementation team was positive so problem has to be somewhere else and most probably on physical switches. The main reason of option "Notify Switch" is to quickly update physical switch mac-address-table (aka CAM) and help physical switch to understand on which physical port VM vNIC is connected. So as another potential culprit was intended physical switch. In our case it was  virtual stack of two HP blade modules 6125XLG.

At the end it has been proven by implementation team that HP switch was the culprit. Here is very important HP switch global configuration setting to eliminate this issue.

 mac-address mac-move fast-update  