Monday, May 05, 2014

DELL Force10 : Initial switch configuration

[ Previous | DELL Force10 : Series Introduction ]

I assume you have serial console access to the switch unit to perform initial switch configuration. I guess it will not impressed you that to switch from read mode to configuration mode you  have to use command
conf
... before continue I would like to recap some important basic FTOS commands we will use later in this blog post. If you want to exit from configuration mode or even from deeper configuration hierarchy you can do it with one or several
exit 
commands which will jump to the upper level of configuration hierarchy and eventually exit conf mode. However the easiest way to leave configuration mode is to use command
end
which will exit configuration mode immediately.

The last but very important and very often used command is
write mem
which will write your running switch configuration to the flash and therefore configuration will survive the switch reload. You can do the same with more general command
copy running-config startup-config
If you want to display running configuration you can use command
show running-config
Whole configuration can be pretty long, so if you are interested only on some part of running configuration you can use following commands
show running-config interface managementethernet 0/0
show running-config interface gigabitethernet 0/2
show running-config spanning-tree rstp
show running-config boot
As you can see FTOS command line interface (cli) is very similar to CISCO.

Ok, so after basics let's start with initial configuration. Switch configuration usually begins with host name configuration. It is generally good practice to use unique host names because you know on which system you are logged in.
hostname f10-s60
As a next step I usually configure management IP settings and enable remote access. You have to decide if you will use in-band management leveraging normal IP settings usually configured on dedicated VLAN interface just for system management or you will leverage dedicated out-of-band management port. In example below you can see
  • out-of-band management port for system management IP settings
  • how to create admin user
  • how to enable ssh to allow remote system management
interface ManagementEthernet 0/0
  ip address 192.168.42.101/24
  no shutdown
exit
management route 0.0.0.0/0 192.168.42.1

username admin password YourPassword privilege 15

ip ssh server enable
Now you have to decide if you want to enforce login for users connected via local console. By default there is no login required which can by security risk especially in environments without strict physical security rules. Below is configuration which enforce local login credentials when using serial console.
 aaa authentication login default local
At this point I would like to note that Force10 switch has all capabilities and features disabled in default factory configuration. That's the reason why for example each switch interface must be explicitly enabled before usage because all interfaces are in shutdown state by default.

Before you enable any switch interface it is good practice to enable spanning tree protocol as security mechanism against potential loops in the network. Once again, spanning tree feature is not enabled by default so you have to do it explicitly. Force10 FTOS has implemented all standard and even some non-standard (CISCO proprietary) spanning tree protocols like PVSTP+. On the latest FTOS version following spanning tree protocols are supported:

  • STP (Spanning Tree Protocol)
  • RSTP (Rapid Spanning Tree Protocol)
  • MSTP (Multiple Spanning Tree Protocol)
  • PVSTP+ (Per-VLAN Spanning Tree Plus)
Bellow is configuration example which enables standard rapid spanning tree protocol (aka RSTP) ...
protocol spanning-tree rstp
  no disable 
Another decision you have to do before implementation is the location from where do you want to boot your switch operating system. On some Force10 models (for example on S60) is default primary boot location TFTP server  ...
boot system stack-unit 0 primary tftp://192.168.128.1/FTOS-SC-8.3.3.7.bin
boot system stack-unit 0 secondary system: A:
boot system stack-unit 0 default system: B:
boot system gateway 192.168.128.1
You can see that primary boot location is TFTP server. If you don't have tens or hundreds of switches you usually don't want to load FTOS remotely from TFTP server but from internal flash in the switch. Although default switch configuration would work because if TFTP server boot fails switch boot sequence continue with secondary location  but it's better to configure the switch boot sequence explicitly base on your requirements. Below is typical boot sequence configuration.
boot system stack-unit 0 primary system: A:boot system stack-unit 0 secondary system: B:boot system stack-unit 0 default system: A: no boot system gateway
Next thing you should check is what FTOS version do you have. Below is the command how you can check it ...
f10-s60#show version
Dell Force10 Networks Real Time Operating System Software
Dell Force10 Operating System Version: 1.0
Dell Force10 Application Software Version: 8.3.3.7
Copyright (c) 1999-2011 by Dell Inc.
Build Time: Sat Nov 26 01:23:50 2011
Build Path: /sites/sjc/work/build/buildSpaces/build20/E8-3-3/SW/SRC
f10-s60 uptime is 4 minute(s)
System image file is "system://A"
System Type: S60
Control Processor: Freescale MPC8536E with 2147483648 bytes of memory.
128M bytes of boot flash memory.
  1 48-port E/FE/GE (SC)
 48 GigabitEthernet/IEEE 802.3 interface(s)
  2 Ten GigabitEthernet/IEEE 802.3 interface(s)
You can see FTOS version 8.3.3.7 which is not the latest one as the latest FTOS version at the time of writing this article is 8.3.3.9 and boot loader 1.0.0.5. It is generally good practice to upgrade FTOS to the latest version before performing verification test and going into production. For the latest version you have to go to http://www.force10networks.com and sign in. If you don't have Force10 account you can register there. Please note that each Force10 switch model use different FTOS versions. So there can be FTOS 9.4.x for model S4810 and 8.3.x for S60.

Now I'll show you how to do FTOS and boot loader upgrade.
FTOS should be upgraded first and Boot Loader later ...
upgrade system tftp: A:
upgrade system stack-unit all A:
(applicable only if you have stack configured)
upgrade boot ftp: (applicable only if  new bootloader compatible with FTOS code exists)
reload
You can check current FTOS version
show version
and if you want to know what FTOS version do you have on which boot bank you can 
show boot system stack-unit 0
By the way, have I told you there are two boot banks? Boot bank A: and boot bank B:so you can choose primary and secondary boot location. We have already covered boot configuration but here it is again ...
conf
  boot system stack-unit 0 primary system: A:
  boot system stack-unit 0 secondary system: B:
FTOS is loaded by boot loader and current Boot Loader can be displayed by command below
show system stack-unit 0
Hope this post is helpful for IT community. In case you have any question, suggestion or idea on improvements please share your thoughts in in the comments.

Stay tuned and wait for next article ...

[ Next | DELL Force10 : Interface configuration and VLANs ]

DELL Force10 : Series Introduction

I have just decided to write dedicated blog post series about DELL Force10 networking. Why?

Who knows me in person is most probably aware that my primary professional focus is on VMware vSphere infrastructure and datacenter enterprise hardware. Sometimes I have discussion with infrastructure experts, managers and other IT folks what is the most important/complex/critical/expensive vSphere component. vSphere component is meant by compute (servers), storage and networking.  I thing it is needless discussion because all components are important and have to be integrated into single integrated system fulfilling all requirements, dealing with known constraints and mitigating all potential risks. Such integrated infrastructures are very often called POD which stands, as far as I know, for Performance Optimized Datacenter. These integrated systems are, from my point of view, new datacenter computers having dedicated but distributed computing, storage and networking components. I would prefer to call such equipment as "Optimized Infrastructure Block" or "Datacenter Computer" because it is not only about performance but also about reliability, capacity, availability, manageability, recoverability and security. We call these attributes infrastructure qualities and whole infrastructure block inherits qualities from sub-components. Older IT folks often compare this concept with main frame architectures however nowadays we usually use commodity x86 hardware "a little bit" optimized for enterprise workloads. 

By the way that's one of the reason I like current DELL datacenter product portfolio because DELL has everything I need to build POD - server, storage systems and now also networking so I'm able to design single vendor infrastructure block with unified support, warranty, etc. Maybe someone don't know but DELL acquired EqualLogic and Compellent storage vendors some time ago, but more importantly for this blog post, DELL also acquired well known (at least in US) datacenter networking producer Force10. For official acquisition details look here.

But back to the networking. Everybody would probably agree that networking is very important part of vSphere infrastructure because of several reasons. It provides interconnect between clustered components - think about vSphere networks like Management, vMotion, Fault Tolerance, VSAN, etc. It also routes network traffic to the outside world. And sometimes it even provides storage fabrics (iSCSI, FCoE, NFS). That's actually the reason why I'm going to write this series of blog posts about DELL Force10 networking - because of networking importance. However I don't want to write about  legacy networking but modern networking approach for next generation virtualized and software defined datacenters.

Modern physical networking is not only about hardware (burned intelligence in ASICs with high bandwidth, fast and low latency interfaces) but also in software. The main software sits inside DELL Force10 switches. It is switch firmware called FTOS - Force10 Operating System (see. for more general information about FTOS look here).  However, today it is not only about switch embedded firmwares but also about whole software ecosystem - managements, centralized control planes, virtual distributed switches, network overlays, etc.
 
In future articles I would like to deep dive into FTOS features, configuration examples and virtualization related integrations.

Next, actually first technical article in this series will be about about typical initial configuration of Force10 switch. I know it is not rocket science but we have to know basics before taking off. In the future I would like to write about more complex designs, capabilities and configurations like
  • Multi-Chassis Link Aggregation (aka MC-LAG). In Force10 terminology we call it VLT - Virtual Link Trunking.
  • Virtual Routing and Forwarding (aka VRF). Some S-series Force10 models with FTOS 9.4 support VRF-lite.
  • some Software Define Networking (aka SDN) capabilities like python/perl scripting inside the switch, REST API, VXLAN hardware VTEP, Integration with VMware Distributed Virtual Switch, Integration with VMware NSX, OpenFlow, etc.
If you prefer some topics please let me know in comments and I'll try to prioritize it. Otherwise I'll write future posts based on my preferences.   
So let's finish blog post series introduction and start some technical stuff and begin with deep dive into switch initial configuration! Just click next and below ...

[ Next | DELL Force10 : Initial switch configuration ]

Tuesday, November 12, 2013

Introduction to the Dell S6000 Layer 2 Gateway for VMware NSX

On following video you can see DELL Force10 S6000 integration with VMware NSX. That's beginning of real and usable software defined networking (SDN) or network virtualization if you wish.


 I'm looking forward for hands-on experience in the future.

Saturday, August 31, 2013

DELL Force10 S6000 as a physical switch for VMware NSX

Based on this  document http://www.vmware.com/files/pdf/products/nsx/vmw-nsx-dell-systems.pdf
DELL Force10 S6000 is going to be fully integrated with VMware NSX (NSX is software defined networking platform).

Dell Networking provides:
  • Data center switches for robust underlays for L2 overlays
  • CLI for virtual and physical networks
  • Network management and automation with Active Fabric Manager
  • S6000 Data Center Switch Gateway for physical workloads to connect to virtual networks
  • Complete end-to-end solutions that include server, storage, network, security, management and services with world wide support
Dell S6000 use cases:
  • Extend virtual networks to physical servers -  S6000 works as VXLAN gateway to VLANs on physical network (VXLAN VTEP).
  • Connect physical workloads reachable on a specific VLAN to logical networks via an L2 service
  • Connect physical workloads reachable on a specific port to logical networks via an L2 service
  • Connect to physical workloads in a Physical to virtual migration
  • Migration from existing virtualized environments to public clouds, creating hybrid clouds
  • Access physical router, firewall, load balancer, WAN optimization and other network resources

I cannot wait to test it in my lab or on customer PoC engagement. After hands-on experience I'll share it on this blog. 

Thursday, June 20, 2013

Force10 Open Automation Guide - Configuration and Command Line Reference

This document describes the components and uses of the Open Automation Framework designed to run on the Force10 Operating System (FTOS), including:
• Smart Scripting
• Virtual Server Networking (VSN)
• Programmatic Management
• Web graphic user interface (GUI) and HTTP Server

http://www.force10networks.com/CSPortal20/KnowledgeBase/DOCUMENTATION/CLIConfig/FTOS/Automation_2.2.0_4-Mar-2013.pdf

Tuesday, June 04, 2013

Software Defined Networking - SDN

SDN is another big topic in modern virtualized datacenter so it is worth to understand what it is and how it can help us to solve real datacenter challenges.

Brad Hedlund's explanation "What is Network Virtualization"
http://bradhedlund.com/2013/05/28/what-is-network-virtualization/
Bred Hedlund is very well known netwoking expert. Now he works for VMware | Nicira participating on VMware NSX product which should be next network virtualisation platform (aka network hypervisor). He is ex-CISCO and ex-DELL | Force10 so there is big probability he fully understand what is going on.

It is obvious that "dynamic service insertion" is the most important thing in SDN. OpenFlow and CISCO vPath is trying to do it but each in different way. Same goal but with different approach. What is better? Who knows? The future and real experience will show us what is better. Jason Edelman's blog post very nicely and clearly compares both approaches.
http://www.jedelman.com/1/post/2013/04/openflow-vpath-and-sdn.html

CISCO as long term networking leader and pioneer has of course its own vision of SDN. Nexus 1000V and Virtual Network Overlays Play for CISCO Pivotal Role in Software Defined Networks. Very nice explanation of CISCO approach is available at
http://blogs.cisco.com/datacenter/nexus-1000v-and-virtual-network-overlays-play-pivotal-role-in-software-defined-networks/


Tuesday, April 16, 2013

Network Overlays vs. Network Virtualization

Scott Lowe published very nice blog post (philosophy reflection) about "Network Overlays vs. Network Virtualization".

And this was my comment to his post ..

Scott, excellent write-up. As always. First of all I absolutely agree that good definitions, terminology, and conceptual view of particular layer is fundamental to fully understand any technology or system. Modern hardware infrastructure is complex and complexity is growing year on year.
Software programming has the same history. Who programs in assembler nowadays? Why we use object oriented programming more then 20 years? The answer is ... to avoid complexity and have control on system behavior. In software MVC model is often use and it stands for Model-View-Controller. Model is logical representation of something we want to run in software, View is simplified model presentation to end user and controller is engine behind the scene. The same concept apply to SDI (Software Defined Infrastructure) where SDN (Software Defined Network) is another example of the same story.
VMware did excellent job with infrastructure abstraction. Everything in VMware vSphere is object. Better to say managed object which has some properties and methods. So it is the model. vSphere Client or Web Client or vCLI or PowerCLI are different user interfaces into the system. So it is View. And who is Controller? Controller is vCenter because it orchestrates system behavior. vCenter controller includes prepackaged behavior (out-of-the-box) but it can be extended by custom scripts and orchestrated externally for example by vCenter Orchestrator. That's what I really love VMware vSphere. And it is from the begining architected to purely represent hardware infrastructure in software constructs.
Now back to Network Virtualization. In my opinion Network Overlay (for example VXLAN) is mandatory  component to abstract L2 from physical switches and have it in software. Particular Network overlay protocol must be implemented in "Network Hypervisor" which is software L2 switch. But "Network Hypervisor" has to implement also other protocols and components to be classified as "Network Virtualization" and not only as just another software vSwitch.
What Scott already mentioned in his post is that networking is not just L2 but also L3-7 network services so all network services must be available to speak about full "Network Virtualization". Am I correct Scott? And I feel the open question in this post ... who is the controller of "Network Virtualization"? :-)