POWER CONTROL
Power on server:ipmitool -I lan -H 192.168.4.5 -U root -P calvin chassis power on
Power off server:
ipmitool -I lan -H 192.168.4.5 -U root -P calvin chassis power off
Server status:
ipmitool -I lan -H 192.168.4.5 -U root -P calvin chassis status
All chassis power Commands:
status, on, off, cycle, reset, diag, soft
SENSORS
List all sensors and their status:
ipmitool -I lan -H 192.168.4.5 -U root -P calvin sdr list
List temperature sensors and their status:
ipmitool -I lan -H 192.168.4.5 -U root -P calvin sdr type temperature
Get temperature from particular sensor id:
ipmitool -I lan -H 192.168.4.5 -U root -P calvin sdr get 'Ambient Temp'
All Sensor Types: Temperature Voltage
Current Fan
Physical Security Platform Security
Processor Power Supply
Power Unit Cooling Device
Other Memory
Drive Slot / Bay POST Memory Resize
System Firmwares Event Logging Disabled
Watchdog System Event
Critical Interrupt Button
Module / Board Microcontroller
Add-in Card Chassis
Chip Set Other FRU
Cable / Interconnect Terminator
System Boot Initiated Boot Error
OS Boot OS Critical Stop
Slot / Connector System ACPI Power State
Watchdog Platform Alert
Entity Presence Monitor ASIC
LAN Management Subsystem Health
Battery Session Audit
Version Change FRU State
Other IPMI commands
Copy from http://www.openfusion.net/linux/ipmi_on_centos.html
# IPMI commands ipmitool help man ipmitool # To check firmware version ipmitool mc info # To reset the management controller ipmitool mc reset [ warm | cold ] # Show field-replaceable-unit details ipmitool fru print # Show sensor output ipmitool sdr list ipmitool sdr type list ipmitool sdr type Temperature ipmitool sdr type Fan ipmitool sdr type 'Power Supply' # Chassis commands ipmitool chassis status ipmitool chassis identify [<interval>] # turn on front panel identify light (default 15s) ipmitool [chassis] power soft # initiate a soft-shutdown via acpi ipmitool [chassis] power cycle # issue a hard power off, wait 1s, power on ipmitool [chassis] power off # issue a hard power off ipmitool [chassis] power on # issue a hard power on ipmitool [chassis] power reset # issue a hard reset # Modify boot device for next reboot ipmitool chassis bootdev pxe ipmitool chassis bootdev cdrom ipmitool chassis bootdev bios # Logging ipmitool sel info ipmitool sel list ipmitool sel elist # extended list (see manpage) ipmitool sel clear
SOL - Serial over LAN (connect to console redirection)
ipmitool -I lanplus -U root -P calvin -H 192.168.2.62 sol activate
ipmitool -I lanplus -U root -P calvin -H 192.168.2.62 sol deactivate
No comments: